HALOGLAS FIR Emissivity
HALOGLAS Far-Infrared (FIR) Glass Series Combined Test
1. Basic Test Overview
Authorized Testing Institution
Wuhan Product Quality Supervision & Inspection Institute National Inspection & Testing Center for Infrared & Industrial Electric Heating Products (CNAS accredited lab)
Unified Test Standard
GB/T 18497.2-2019, GB/T 7287-2008
Test Core Indicators
Normal total emissivity (measured at 40℃)
Full infrared radiation spectrum range (2.5 μm – 25 μm)
Tested HALOGLAS Product Samples (3 batches)
| Report No. | Sample Name | Test Date | Sample Quantity |
|---|---|---|---|
| (2025)WT-HW-01087 | Far-infrared energy glass bowl | 2025-10-23 | 1 pc |
| (2025)WT-HW-01271 | Far-infrared energy glass rod | 2025-12-11 | 3 pcs |
| (2022)WT-HW-00384 | Far-infrared glass tumbler | 2022-05-24 | 1 pc |
Test Environment
Bowl & tumbler: 22℃, 46%–49% RH
Glass rod: 20℃, 42% RH
Test Principle
Detect the material’s infrared radiation performance at 40℃ (simulating daily human body/liquid contact temperature). The normalized spectrum records relative radiation intensity across 2.5–25 μm medium & long infrared waveband, which covers the biologically active far-infrared band (4–14 μm).
2. Key Measured Data – Normal Total Emissivity
Normal total emissivity is the core metric of far-infrared radiation efficiency (higher value = stronger far-infrared energy release):
Glass bowl [(2025)WT-HW-01087]: 0.88 @ 40℃
Glass rod [(2025)WT-HW-01271]: 0.87 @ 40℃
Glass tumbler [(2022)WT-HW-00384]: 0.86 @ 40℃All samples reach high emissivity above 0.85, representing excellent far-infrared radiative capacity.
3. Infrared Spectrum Uniform Characteristics (All 3 Products)
Full test wavelength range: 2.5 μm ~ 25 μm
Radiation peak position: Global maximum relative radiation intensity appears at 8.0–8.5 μm, inside the classic biological far-infrared active zone (4–14 μm).
Spectrum trend consistency across bowl, rod and tumbler:
Weak radiation below 4 μm; multiple small absorption/radiation peaks at 5–6.5 μm;
Sharp intensity rise from 7 μm, hitting peak at 8–8.5 μm;
Gradual steady decline after 10 μm, continuous weak long-wave infrared radiation extending to 25 μm.
All HALOGLAS product forms share identical infrared radiation spectral curves, proving stable, consistent far-infrared functional formula across rod, bowl, tumbler variants.
4. Official Report General Clauses
Reports are only valid with official institute inspection special seal and complete tester/reviewer/approver signatures; altered/partial copies are invalid.
All sample information is provided by the applicant; the laboratory bears no responsibility for data authenticity.
Test data is only valid for the submitted physical samples, not all batch products.
Objections to test results must be submitted to the institute within 15 calendar days after receiving the report.
Entrusted test reports cannot be used for judicial appraisal or quality arbitration.
5. Comprehensive Performance Conclusion
All three HALOGLAS product forms (rod, bowl, tumbler) deliver high normal total emissivity (0.86–0.88 at 40℃), confirming strong far-infrared emission performance.
Their infrared spectrum concentrates peak radiation within the bioactive 4–14 μm band, the wavelength range recognized to resonate with water molecules and human tissue.
Consistent spectral curves across different product shapes verify the uniform far-infrared functional formula of HALOGLAS energy glass material.
The complete series meets national infrared product testing standards, providing objective third-party lab proof of the core far-infrared functional claim of HALOGLAS.
Effect on Human Thermal and Blood Microcirculation
HALOGLAS Far-Infrared Bracelet Thermal & Microcirculation Improvement Test
1. Basic Test Information
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Basic Info
Report No.: BJY251231-9180501-01
Issued Date: Jan 16, 2026
Sample Submission Date: Dec 31, 2025
Test Type: Commissioned human volunteer trial inspection
Client & Manufacturer
HEBEI MSD GLASS TECHNOLOGY Co., Ltd
Test Sample
Name: Optical Wave Far-Infrared Energy Glass Bracelet
Sample Quantity: 1 piece
Test Environment
Ambient temperature: 23 ± 2 ℃; Relative humidity: 50 ± 5%RH
Test Item
Thermal effect on human skin & blood microcirculation improvement performance
Test Methodology
Self-controlled contrast experiment: Recruit 10 healthy volunteers to continuously wear the HALOGLAS bracelet for 7 consecutive days. Testing equipment: Infrared thermal imager + laser blood flow analyzer Monitor 3 core wrist indicators before use vs. after 7-day continuous wear:
Wrist surface temperature
Wrist blood flow volume (Unit: PU)
Wrist blood flow velocity (Unit: AU)
2. Detailed Test Data & Results
2.1 Thermal Effect Test Conclusion
Infrared thermography observation: All volunteers presented varying degrees of elevated wrist skin temperature after 7 days of wearing the bracelet.Judgment: The far-infrared glass bracelet produces obvious thermal warming effect on human skin surface.
2.2 Wrist Blood Flow Volume Comparison (PU)
Volunteer | Before Use | After 7 Days Wear | Change Trend |
1 | 142.7 | 151.9 | Rise |
2 | 104.7 | 161.3 | Rise |
3 | 224.4 | 328.2 | Rise |
4 | 289.7 | 229.9 | Drop |
5 | 41.4 | 776.3 | Rise |
6 | 167.4 | 609.9 | Rise |
7 | 174.7 | 195.7 | Rise |
8 | 351.9 | 147.6 | Drop |
9 | 275.0 | 481.9 | Rise |
10 | 144.2 | 182.0 | Rise |
Statistics: 8 out of 10 volunteers (80%) had increased wrist blood flow after wearing the bracelet.
2.3 Wrist Blood Flow Velocity Comparison (AU)
Volunteer | Before Use | After 7 Days Wear | Change Trend |
1 | 36.9 | 32.8 | Drop |
2 | 40.4 | 30.3 | Drop |
3 | 38.1 | 44.1 | Rise |
4 | 59.3 | 61.8 | Rise |
5 | 9.3 | 45.2 | Rise |
6 | 46.2 | 56.6 | Rise |
7 | 21.5 | 32.4 | Rise |
8 | 89.7 | 82.4 | Drop |
9 | 91.7 | 94.6 | Rise |
10 | 36.8 | 30.5 | Drop |
Statistics: 6 out of 10 volunteers (60%) showed improved blood flow velocity after wearing the bracelet.
2. Official Integrated Test Conclusion
The HALOGLAS far-infrared energy glass bracelet delivers a noticeable warming thermal effect on human skin surface.
For most test subjects, long-term wearing can increase wrist blood flow volume and blood flow velocity, proving it has a certain effect on improving human peripheral blood microcirculation.
3. Report Validity Remarks
This report is only valid with official red special seal and unique anti-counterfeit verification code; authenticity can be checked via designated official website.
All test results only apply to the submitted single bracelet sample, and the data reflects performance under this 10-volunteer trial condition.
The report shall be signed by tester, reviewer and approver to take full legal effect; alteration or partial copying invalidates the document.
4. Comprehensive Performance Summary
Human body volunteer trials confirm the core far-infrared thermal function of HALOGLAS optical wave glass, which can raise local skin temperature through far-infrared radiation.
80% of test subjects achieved higher blood flow volume, and 60% gained faster blood flow speed after continuous 7-day wear, verifying its auxiliary microcirculation-improving function for human wrists.
The test provides human-body experimental data supporting the health-care attribute of HALOGLAS far-infrared wearable accessories.
FDA Compliance
HALOGLAS Material US FDA Lead & Cadmium Leaching Test
Basic Test Overview
Testing Laboratory
SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd. (Member of SGS Global Group)
Report Identifiers
Main Report No.: TSNHL26000834001
Internal SGS Lab ID: TJHL2603001648CW
Report Issued Date: March 12, 2026
Sample Receipt Date: March 06, 2026
Test Cycle: Mar 06 – Mar 12, 2026
Applicant & Manufacturer
HEBEI MSD GLASS TECHNOLOGY CO., LTD., Hejian City Economic Development Zone, Hebei Province, China
Test Sample
Sample ID: A1 (TSN26-0008340-0001.C001)
Material: Yellow HALOGLAS energy glass rod (flatware category per FDA definition)
Test Mandate
Detect leachable Lead (Pb) and Cadmium (Cd) to comply with US FDA CPG Sec.545.400 & CPG Sec.545.450 (food contact glassware safety standards)
Test Methodology
Reference Standard: AOAC 973.32-1977 (1996)
Detection Instrument: AAS / ICP-OES
Sample Treatment: 6 parallel extraction replicates with 172 mL extraction solution per replicate
Definition Key Terms
RL = Reporting Limit; ND = Not Detected (< RL)
Flatware: Non-fillable articles or shallow fillable items with internal depth ≤25 mm (sample classified as flatware)
Compliance Rule: ILAC-G8:09/2019 Binary Simple Acceptance Rule
2. Detailed Test Results
Detection Reporting Limits & Regulatory Limits
| Analyte | Reporting Limit (RL, µg/mL) | FDA Permitted Maximum Limit (µg/mL) |
|---|---|---|
| Leachable Lead (Pb) | 0.05 | 3.0 |
| Leachable Cadmium (Cd) | 0.01 | 0.5 |
Six Parallel Extraction Test Data
All six replicate samples recorded identical non-detectable results:
Pb: <0.05 µg/mL; Cd: <0.01 µg/mL
Pb: <0.05 µg/mL; Cd: <0.01 µg/mL
Pb: <0.05 µg/mL; Cd: <0.01 µg/mL
Pb: <0.05 µg/mL; Cd: <0.01 µg/mL
Pb: <0.05 µg/mL; Cd: <0.01 µg/mL
Pb: <0.05 µg/mL; Cd: <0.01 µg/mL
Average Test Result
Average leachable Lead: <0.05 µg/mL (far below 3.0 µg/mL limit)
Average leachable Cadmium: <0.01 µg/mL (far below 0.5 µg/mL limit)
Official Compliance Outcome
Test conclusion marked Pass for US FDA CPG Sec.545.400 and CPG Sec 545.450 requirements for flatware glass products.
3. Report Validity Remarks
All sample information and material description are provided by the client; SGS assumes no liability for authenticity of client-supplied data.
Test results apply solely to the submitted yellow HALOGLAS glass rod sample tested.
Full report validity relies on the official SGS Inspection & Testing Services special stamp, authorized signatory signature, and complete original documentation; partial copies without official seal are invalid.
A physical photo of the tested glass rod sample is attached on Page 4 of the original report for traceability verification.
4. Comprehensive Conclusion
The HALOGLAS yellow energy glass material shows no detectable leachable lead and cadmium under FDA standard extraction testing, with all replicate readings below the instrument reporting limits.
Measured heavy metal leaching levels are drastically lower than the maximum permissible thresholds set by US FDA for food-contact glass flatware.
The product fully meets US FDA food safety regulations for lead and cadmium migration, confirming safe food-contact application for the HALOGLAS glass material in US market access.
Skin Irritation ; Sensitization Safe
HALOGLAS Energy Block Skin Biocompatibility Test
1. Basic Test Overview
Testing Institution
Guangdong Detection Center of Microbiology
Report Information
Report No.: 2026FM04534R01E
Verification Code: E7WS8U3Q
Sample Receipt Date: 2026-03-13
Test Completion Date: 2026-05-06
Issuance Date: 2026-05-06
Applicant & Manufacturer
HEBEI MSD GLASS TECHNOLOGY CO., LTD., Hejian City Development Zone, Hebei Province, China
Test Sample
Name: HALOGLAS Energy block
Appearance: Nubby solid block
Test Quantity: 12 pieces
Test Items
Guinea pig closed patch skin sensitization test
Rabbit repeated exposure skin irritation test
Applicable International & National Standards
Skin Sensitization: ISO 10993-10:2021 (Clause 6.6)
Skin Irritation: GB/T 16886.23-2023 / ISO 10993-23:2021 (Clause 7.2)
Test Substance Preparation
Per GB/T 16886.12-2023: Mix sample and sterile water at ratio 0.2 g/mL; extract at 37℃ for 72 hours, and the aqueous extract is used as test liquid.
Animal Experiment Qualification
Laboratory Animal Use License: SYXK (Guangdong) 2021-0156; Test environment: 20–26℃, RH 30–70%.
2. Test 1: Skin Sensitization (Closed Patch Test, Guinea Pig Model)
Test Animals
16 conventional albino guinea pigs (8 male + 8 female), weight 300–500 g, quarantined for 5 days before testing.
Test Groups
Test group (10 guinea pigs): HALOGLAS aqueous extract
Negative control group (6 guinea pigs): Sterile extraction medium only
Positive control group (10 guinea pigs): DNCB (2,4-dinitrochlorobenzene, known sensitizer)
Test Protocol
Induction phase: Occlusive patch application for 6 hours daily, repeated 3 consecutive weeks.
Challenge phase: Single occlusive patch 14 days after final induction, 6-hour exposure.
Skin scoring at 2 h and 48 h post patch removal using Magnusson & Kligman grading scale (0 = no reaction; 3 = severe erythema + swelling).
Test Results
All 10 guinea pigs in the test group scored 0 (no erythema, no swelling) at both 24h+2h and 48h observation points; sensitization rate = 0%.
Negative control group also showed zero skin reactions.
Positive control group produced obvious skin erythema/swelling, confirming test validity.
Test Conclusion
Under test conditions, HALOGLAS extract triggers no skin sensitization response in guinea pigs.
3. Test 2: Repeated Exposure Skin Irritation Test (Rabbit Model)
Test Animals
3 female New Zealand rabbits, weight 2.0–2.8 kg, quarantined for 3 days before testing.
Test Protocol
Single exposure phase: 4-hour occlusive patch, observe skin at 1h, 24h, 48h, 72h post removal.
Repeated exposure phase: Daily 4-hour patch application for 14 consecutive days; record skin condition before each application and 1 hour after each patch removal.
Final observation: 24h, 48h, 72h after the 14th exposure.
Calculate Primary Irritation Index and Cumulative Irritation Index based on erythema & edema scores.
Test Results
At all observation time points (single exposure + 14-day repeated exposure), all test sites on all rabbits recorded a score of 0 (no erythema, no edema).
Primary irritation index of sample = 0; Cumulative irritation index of sample = 0.
Test Conclusion
A cumulative irritation index of 0 falls under the category of negligible skin irritation. The HALOGLAS extract causes no skin irritation after short single contact or long-term repeated contact.
4. Official Report General Remarks
Report is invalid without official testing seal, page seal, and complete signatures of editor, verifier and approver.
Alteration, deletion or supplementation renders the report void; full reproduction only permitted with written lab approval.
All test results are exclusively valid for the submitted HALOGLAS energy block samples.
Disputes must be submitted to the testing institute within 15 days upon report receipt.
Sample information is provided by the applicant; the laboratory takes no responsibility for its authenticity.
5. Comprehensive Biocompatibility Summary
Sensitization safety: The HALOGLAS material has zero sensitization potential; it will not induce delayed allergic skin reactions per ISO 10993-10 standard.
Irritation safety: Neither one-time nor daily repeated skin contact triggers erythema or swelling, with a cumulative irritation index of 0, classified as negligible irritation.
Biocompatibility performance: The material fully meets international ISO 10993 medical device skin safety standards, proving it is mild, non-irritating and non-allergenic for direct skin contact applications.
LFGB EU Compliance
HALOGLAS Energy Material LFGB Food Contact Safety Test
1. Basic Test Overview
Testing Body
SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd., member of global SGS Group
Report Identifiers
Main Report No.: TSNHL26000834201
Internal SGS Lab ID: TJHL2603001649CW
Issued Date: March 12, 2026
Sample Receipt: March 06, 2026
Test Period: Mar 06 – Mar 12, 2026
Applicant & Manufacturer
HEBEI MSD GLASS TECHNOLOGY CO., LTD., Hejian City Economic Development Zone, Hebei Province, China
Test Sample
Sample ID: A1 (TSN26-0008342-0001.C001)
Material: Yellow HALOGLAS energy glass rod, classified as flatware (internal depth ≤25 mm)
Regulatory Frameworks
EU Regulation (EC) No 1935/2004 (Food Contact Materials & Articles)
German LFGB (Food, Commodities and Feed Code §30, §31 + BfR Recommendations)
Three Test Modules Conducted
Sensory test (odour & taste) per DIN 10955:2024
Leachable Lead & Cadmium per DIN 51032:2017 / EN 1388-2:1995 (AAS/ICP-OES detection)
Leachable Cobalt per ALS Opinion 2017/15 / EN 1388-2:1995 (ICP-OES detection)
Test Compliance Rule
ILAC-G8:09/2019 Binary Simple Acceptance Rule
2. Detailed Test Results by Module
Module 1: LFGB Sensory Examination (Odour & Taste)
Test Medium: Distilled water, 100℃ soaking for 2 hours
Test Panel: 6 professional assessors
Evaluation Scale: 0 = no perceptible difference; max allowed limit = 2.5
Test Results:
Odour intensity score: 0
Taste intensity score: 0
Outcome: Pass
Interpretation: No foreign odour or flavour migration from the glass material under high-temperature aqueous contact.
Module 2: Leachable Lead & Cadmium (4% Acetic Acid Extraction)
Extraction condition: 187 mL 4% acetic acid simulating acidic food contact Unit: mg/dm² (flatware limits per LFGB glass tableware standard)
| Analyte | Measured Value | LFGB Permitted Limit | Compliance |
|---|---|---|---|
| Lead (Pb) | <0.1 | 0.8 | Pass |
| Cadmium (Cd) | <0.01 | 0.07 | Pass |
| All heavy metal migration levels are far below legal thresholds for glass flatware. |
Module 3: Leachable Cobalt
Extraction volume: 187 mL 4% acetic acid; tested surface area = 1.12 dm²
Analyte Measured Value Permitted Limit Compliance Cobalt (Co) <0.01 mg/dm² 0.02 mg/dm² Pass Cobalt migration is below half the regulatory limit, meeting EU & German LFGB requirements.
3. General Report Remarks
All sample material descriptions are provided by the client; SGS bears no responsibility for authenticity of client-provided data.
Test results are only valid for the submitted yellow HALOGLAS glass rod sample shown in the attached photo on Page 5.
The report is only legally valid with the official SGS Inspection & Testing Services special stamp; partial copies without the full seal are invalid.
Abbreviation definitions: RL = Reporting Limit; ND = Not Detected (< RL); < = less than the stated value.
4. Comprehensive Conclusion
The HALOGLAS yellow energy glass fully complies with German LFGB and EU Regulation (EC) No 1935/2004 for food-contact glass flatware, passing all three test categories.
Sensory testing confirms no off-odour or off-taste transfer during hot water contact, ensuring no impact on food flavour.
Leachable lead, cadmium and cobalt are all undetectable or present at trace concentrations well under official legal limits, eliminating risks of heavy metal contamination in food contact scenarios.
The material meets European food safety standards and is eligible for market access in Germany and the wider EU as food-contact glass tableware.
Heavy Metal Jewelry/Glass Safety
HALOGLAS Far-Infrared Energy Glass GB 4806.5-2016 Food Contact Safety Test
1. Basic Test Overview
Testing Institution
SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd. (CNAS & ILAC-MRA accredited laboratory)
Report Identification
Main Report No.: TSNHL26000522501
Internal SGS Lab ID: TJHL2602001052CW
Issued Date: February 10, 2026
Sample Receipt Date: February 04, 2026
Test Cycle: Feb 04 – Feb 10, 2026
Applicant & Manufacturer
HEBEI MSD GLASS TECHNOLOGY CO., LTD., Construction South Street, Development Zone, Hejian City, Hebei Province, China
Test Sample
Sample ID: a1 (TSN26-0005225-0001.C001)
Material: Light yellow far-infrared energy optical wave glass rod, classified as cooking ware under GB 4806.5-2016
Governing Standard
GB 4806.5-2016 National Food Safety Standard – Glass Products for Food Contact Use
Test Items
Sensory requirement inspection (appearance)
Specific migration of lead (Pb) and cadmium (Cd) heavy metals
Test Methods for Heavy Metal Migration
Lead migration: GB 31604.34-2016 Part 2 Method II
Cadmium migration: GB 31604.24-2016 Method II
Test Extraction Condition
4% acetic acid simulant, 98°C constant temperature, 120 minutes soaking; extraction volume = 225 mL
Compliance Evaluation Rule
ILAC-G8:09/2019 Binary Simple Acceptance Rule
Supplementary Note
This English report corresponds to Chinese version TSNHL26000522502; in case of text inconsistency, the Chinese version shall prevail.
2. Detailed Test Results
2.1 Sensory Appearance Inspection
Standard requirement: Glassware shall be free of flashes, cracks, gaps and visible surface defects Test Result: Compliant Conclusion: Pass
2.2 Specific Migration of Lead & Cadmium (Cooking Ware Limit Standard)
Unit: mg/L
| Analyte | Tested Migration Value | GB 4806.5-2016 Legal Limit for Cooking Ware | Compliance Result |
|---|---|---|---|
| Lead (Pb) | <0.1 | 0.5 | Pass |
| Cadmium (Cd) | <0.01 | 0.05 | Pass |
| All heavy metal migration values are far below the national mandatory limits for glass cooking utensils. |
3. Official Report General Terms
All material descriptions and sample information are provided by the client; SGS is not liable for the authenticity of client-supplied data.
Test results are only valid for the submitted light yellow glass rod sample with attached physical photo on Page 5.
The report is only valid with SGS official inspection & testing special seal; partial copies without full seal are invalid.
Definition of symbols:
<= less than reporting limit; RL = Reporting Limit; ND = Not Detected (< RL).
4. Comprehensive Safety Conclusion
The HALOGLAS far-infrared energy glass fully meets China’s mandatory national food contact glass standard GB 4806.5-2016, passing both appearance sensory check and heavy metal migration tests.
Under high-temperature acidic extraction simulating cooking scenarios, lead and cadmium migration levels are extremely low and well within legal safety thresholds, eliminating heavy metal contamination risks during food heating and preparation.
The material satisfies domestic Chinese food contact safety requirements and can be legally used as glass cooking utensils for domestic market sales.
Antibacterial Capability
HALOGLAS Photocatalytic Antimicrobial Performance Combined Test
1. Basic Test Information
Testing Laboratory
Guangdong Detection Center of Microbiology
Applicant & Manufacturer
HEBEI MSD GLASS TECHNOLOGY CO., LTD., Hejian City, Hebei Province, China
Unified Test Standard
GB/T 30706-2014 Measurement method and evaluation for antibacterial properties of visible-light photocatalytic materials
Test Principle
Compare viable bacterial counts of blank control groups and HALOGLAS test samples after 24-hour incubation under bright (2500 lx visible light) and dark environments separately. Two core metrics are calculated:
Fluorescent antibacterial rate: Antibacterial efficacy under light irradiation
Total antibacterial rate (Rtotal): Comprehensive antibacterial performance covering light & dark conditions Standard judgment rules:
Rtotal ≥ 99%: Strong antibacterial effect
90% ≤ Rtotal < 99%: Qualified antibacterial effect
Rtotal < 90%: Unqualified / weak inhibitory effect
Test Samples & Batch Reports
Report No. 2026SP01074R01E / 2026SP01074R02E
Sample: HALOGLAS Far-Infrared Energy Block (nubbly shape, 30 pieces)
Receipt: 2026-02-02; Issued: 2026-02-26
Test strains: Escherichia coli AS1.90, Staphylococcus aureus AS1.89
Report No. 2026ZD00436R01E
Sample: HALOGLAS block piece (block shape, 12 pieces)
Receipt: 2026-04-03; Issued: 2026-04-30
Test strain: Candida albicans ATCC 10231 (pathogenic fungus)
2. Strain-by-Strain Detailed Test Results
2.1 Escherichia coli AS1.90 (Gram-negative bacteria)
| Testing Indicator | Numerical Result |
|---|---|
| Initial inoculation count (0h control) | 9.6 × 10⁴ cfu/piece |
| Bright control viable count (24h) | 7.0 × 10⁶ cfu/piece |
| Bright test sample viable count (24h) | 1.8 × 10² cfu/piece |
| Dark control viable count (24h) | 7.8 × 10⁶ cfu/piece |
| Dark test sample viable count (24h) | 5.6 × 10⁶ cfu/piece |
| Fluorescent antibacterial rate | 99% |
| Total antibacterial rate (Rtotal) | 99% |
| Judgment: Meets GB/T 30706-2014; the sample has a strong antibacterial effect against E. coli. |
2.2 Staphylococcus aureus AS1.89 (Gram-positive bacteria)
| Testing Indicator | Numerical Result |
|---|---|
| Initial inoculation count (0h control) | 1.3 × 10⁵ cfu/piece |
| Bright control viable count (24h) | 8.6 × 10⁶ cfu/piece |
| Bright test sample viable count (24h) | 2.4 × 10⁵ cfu/piece |
| Dark control viable count (24h) | 9.0 × 10⁶ cfu/piece |
| Dark test sample viable count (24h) | 9.6 × 10⁵ cfu/piece |
| Fluorescent antibacterial rate | 75% |
| Total antibacterial rate (Rtotal) | 97% |
| Judgment: Rtotal ≥90%, complies with standard; the sample has valid antibacterial activity against S. aureus. |
2.3 Candida albicans ATCC 10231 (Pathogenic fungus)
Test light intensity: 2500 lx
| Testing Indicator | Numerical Result |
|---|---|
| Blank control viable count (0h) | 1.8 × 10⁵ cfu/piece |
| Bright control viable count (24h) | 7.4 × 10⁵ cfu/piece |
| Bright test sample viable count (24h) | 1.7 × 10⁵ cfu/piece |
| Dark control viable count (24h) | 9.2 × 10⁵ cfu/piece |
| Dark test sample viable count (24h) | 1.8 × 10⁵ cfu/piece |
| Fluorescent antibacterial rate | 5.6% |
| Total antibacterial rate (Rtotal) | 77% |
| Judgment: Shows moderate inhibitory performance against Candida albicans fungus. |
3. Uniform Report Validity Clauses
The report is invalid without official testing special stamp, page seal, and complete signatures of editor, verifier and approver.
Any addition, deletion or alteration voids the report; full reproduction requires written laboratory approval.
Test conclusions only apply to the physical samples submitted for testing.
Disputes must be submitted to the testing center within 15 days after report issuance.
All sample descriptions are provided by the applicant, and the laboratory does not verify their authenticity.
4. Comprehensive Antimicrobial Summary
For common harmful bacteria widely found in daily environments:
Excellent strong bactericidal performance against gram-negative E. coli (99% total antibacterial rate);
Effective inhibition against gram-positive Staphylococcus aureus (97% total antibacterial rate, above the 90% standard threshold).
The material produces obvious photocatalytic antibacterial effects under visible light; antibacterial potency is significantly higher in bright conditions than dark environments.
For the fungus Candida albicans, HALOGLAS achieves a 77% total inhibition rate, delivering moderate antifungal capacity.
The HALOGLAS far-infrared energy glass complies with the national photocatalytic antibacterial standard GB/T 30706-2014 for routine pathogenic bacteria, verifying its built-in self-cleaning and antibacterial functional properties.
Chemical Resistance
HALOGLAS Glass Chemical Resistance Combined Test
Covers: 98℃ Water Resistance, Acid Resistance, Alkali Resistance Tests
1. Basic Test Overview
Participated Accredited Laboratories
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. (MA certified, Report: SHHL2308041290CW) – 98℃ Glass Granule Water Resistance
Lelangtek Testing Technology Co., Ltd. (CNAS L10366, Reports: AL26010000801 / AL26010047101) – Acid & Alkali Resistance
Applicant & Manufacturer
HEBEI MSD GLASS TECHNOLOGY CO., LTD.
Unified National Standards Applied
GB/T 6582-2021 Glass — Test method and classification of hydrolytic resistance of glass grains at 98 ℃ (Water resistance)
GB 17762-2022 Safety Requirements for Heat-resistant Glassware (Acid & Alkali resistance)
Tested HALOGLAS Samples
FIR glass grains / tumbler blank (for 98℃ water resistance test)
260ml men’s portable borosilicate tumbler (alkali resistance test)
220ml women’s portable borosilicate tumbler (acid resistance test)
Core Test Principle
Simulate long-term contact with hot water, acidic drinks (fruit juice, vinegar) and alkaline liquids (alkaline beverages, cleaning water) under high temperature; evaluate glass corrosion degree via alkali precipitation & weight loss, then grade chemical stability per national standard classification.
2. Separate Detailed Test Data & Results
2.1 98℃ Glass Granule Water Resistance (SGS Report SHHL2308041290CW)
Test Condition: 98℃ boiling water hydrolysis test with 2.00g dry glass grains per parallel group, 3 parallel samples
Titration reagent: 0.01 mol/L HCl solution
Blank consumption value: 0.15 mL/g
Average consumption after blank deduction: 0.1 mL/g
Final Grade: HGB1 (Highest water resistance grade for glass)
Conclusion: Extremely low alkali precipitation under boiling hot water, excellent high-temperature water stability.
2.2 Alkali Resistance Test (Lelangtek AL26010000801, 260ml Men’s Tumbler)
Standard Item: GB 17762-2022 Alkali resistance performance
Test Grade: Class A2
Judgment: Compliant
Meaning: Resists erosion from alkaline liquids without surface degradation or substance precipitation.
2.3 Acid Resistance Test (Lelangtek AL26010047101, 220ml Women’s Tumbler)
Standard Item: GB 17762-2022 Acid resistance (gravimetric method)
Test Grade: Class H3 (Top acid resistance classification)
Meaning: Outstanding anti-corrosion performance against all common acidic food & beverages.
3. Uniform Official Report Clauses
All test results are only valid for the submitted physical samples, not full production batches.
Reports take effect only with official inspection special seal and full authorized signatures; altered data or partial copies are invalid.
Objections to test results must be submitted in writing within 15 working days after report issuance.
All sample descriptions are provided by the applicant; laboratories do not verify their authenticity.
Compliance judgment follows ILAC-G8:09/2019 simple binary acceptance rule.
4. Comprehensive Chemical Resistance Conclusion
HALOGLAS borosilicate glass achieves top-tier ratings in three core chemical stability tests: HGB1 boiling water resistance, Class A2 alkali resistance, Class H3 acid resistance, fully complying with China national heat-resistant glass safety standards.
Minimal alkali ion precipitation occurs even under 98℃ long-term hot water immersion; the glass surface will not corrode or dissolve harmful substances when contacting acidic/alkaline drinks daily.
Superior chemical durability guarantees long-term safe use as food-contact tumblers, cups and tableware, avoiding contamination from glass erosion during daily use.
urability guarantees long-term safe use as food-contact tumblers, cups and tableware, avoiding contamination from glass erosion during daily use.
Anti-inflammatory Performance.
HALOGLAS Far-Infrared Energy Beads Anti-Inflammation Cell Test
1. Basic Test Overview
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Basic Information
Report No.: BJY260127-9180201
Issued Date: Feb 25, 2026
Sample Submission Date: Jan 27, 2026
Test Sample: HALOGLAS Far-Infrared Energy Beads
Test Type: Commissioned cellular experiment inspection
Test Environment: 23 ± 2 ℃, 50 ± 5% RH
Core Test Purpose
Evaluate the anti-inflammatory capacity of HALOGLAS far-infrared material via Raw264.7 macrophage cell inflammation model induced by LPS endotoxin.
Experimental Group Design
Normal Control Group: Untreated healthy cells
Model Group: Cells induced by LPS to build inflammatory damage model (no sample irradiation)
Sample Intervention Group: LPS-injured cells continuously irradiated by HALOGLAS beads (1–2 cm above cell plate) for 24h / 48h / 72h
Key Detection Indexes
Cell viability / proliferation rate (CCK-8 method)
Expression levels of two core inflammatory factors: TNF-α, IL-6 (ELISA microplate assay)
2. Detailed Cell Viability Test Data
Cell viability benchmark: Normal control group = 100%
Group | 24h Average Viability | 48h Average Viability | 72h Average Viability |
Control | 100.00% | 100.00% | 100.00% |
LPS Model | 74.18% | 64.09% | 61.04% |
HALOGLAS Sample | 88.75% | 84.62% | 86.65% |
Data Analysis
LPS severely damages cells, viability drops sharply with prolonged culture (P<0.01, extremely significant difference vs control).
After HALOGLAS far-infrared irradiation, cell viability rises obviously at all time points:
+14.57% higher at 24h vs model group
+20.53% higher at 48h vs model group
+25.61% higher at 72h vs model group
Conclusion: HALOGLAS material significantly alleviates LPS-induced cell damage and protects inflammatory cells.
3. Inflammatory Factor (TNF-α & IL-6) Test Results
Unit: pg/mL
24-hour Test
Group | Mean TNF-α | Mean IL-6 |
Control | 14.60 | 15.39 |
Model | 825.17 | 662.96 |
Sample | 582.95 | 354.01 |
48-hour Test
Group | Mean TNF-α | Mean IL-6 |
Control | 15.55 | 17.83 |
Model | 851.91 | 700.76 |
Sample | 594.26 | 295.07 |
72-hour Test
Group | Mean TNF-α | Mean IL-6 |
Control | 14.08 | 19.46 |
Model | 961.22 | 669.05 |
Sample | 364.50 | 233.48 |
Data Analysis
LPS stimulation causes massive release of pro-inflammatory TNF-α and IL-6 (P<0.01 vs blank control).
Continuous HALOGLAS far-infrared irradiation remarkably suppresses secretion of both inflammatory cytokines at all three time points, showing obvious anti-inflammatory activity.
Anti-inflammatory effect strengthens with extended irradiation time (72h group has the lowest inflammatory factor concentration).
4. Official Report General Remarks
The report is valid only with official red test seal, unique anti-counterfeit code, and complete signatures of tester, reviewer and approver; tampered/partial copies are invalid.
All data only reflect test performance of submitted HALOGLAS bead sample under this cellular experiment condition, not clinical medical proof.
This document is for scientific research & internal product development reference only, cannot be used for judicial dispute, rights protection or medical diagnosis evidence.
The report’s validity period is 12 months from issuance date.
5. Comprehensive Anti-Inflammation Conclusion
Cellular level experiments confirm HALOGLAS far-infrared energy beads deliver clear anti-inflammatory performance.
The material can effectively reduce the release of key pro-inflammatory mediators TNF-α and IL-6, while recovering the viability of damaged inflammatory macrophages.
Its cell protection and inflammation inhibition effects enhance with prolonged far-infrared irradiation time, providing laboratory cellular evidence for the material’s soothing & anti-inflammatory functional attribute.
Promote GABA Secretion Promotion
HALOGLAS Far-Infrared Energy Beads GABA Secretion Promotion Test
1. Basic Test Information
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Details
Report Number: BJY260127-9180201-01
Issued Date: Mar 31, 2026
Sample Receipt Date: Jan 27, 2026
Test Sample: HALOGLAS Far-Infrared Energy Beads
Test Category: Commissioned cellular biological test
Test Environment: 23 ± 2 ℃, relative humidity 50 ± 5%RH
Test Objective
Verify whether HALOGLAS far-infrared material can promote the secretion of γ-aminobutyric acid (GABA) in hypothalamic GT1-7 neuronal cells.
Test Cell & Group Setup
Test cell line: GT1-7 hypothalamic neurons Two experimental groups:
Control Group: Normal neuronal cells without far-infrared irradiation
Sample Intervention Group: Cells continuously irradiated by HALOGLAS beads placed 1–2 cm above culture plate for 24h / 48h / 72h
Detection Method
GABA ELISA assay kit was used to measure intracellular GABA concentration (unit: pg/mL) after different irradiation durations.
2. Complete Test Data
Data Analysis
After 24h, 48h and 72h of continuous far-infrared irradiation from HALOGLAS beads, the intracellular GABA content of neuronal cells is significantly higher than the control group (P<0.01, extremely significant statistical difference).
The strongest GABA-promoting effect appears at the 48-hour irradiation stage, with GABA concentration increased by nearly 80% compared to untreated cells.
The promoting effect remains obvious at 24h and 72h, proving the material has stable efficacy to boost GABA secretion.
3. Official Report Remarks
The report is only valid with the official red special test seal, unique anti-counterfeit code and complete signatures of preparer, reviewer and approver; altered or partial copies are invalid.
All test results only apply to the submitted HALOGLAS bead sample under this cell experiment condition, not clinical human medical evidence.
This document is only for scientific research, product development and internal reference, and cannot be used for litigation, medical diagnosis or rights protection.
The report is valid for 12 months from the date of issuance.
4. Comprehensive Test Conclusion
Cellular laboratory tests prove that HALOGLAS far-infrared energy beads can significantly stimulate hypothalamic neuronal cells to secrete more GABA (γ-aminobutyric acid), a neurotransmitter associated with calming and soothing effects. The promotion effect peaks after 48 hours of continuous irradiation, providing cell-level experimental evidence for the material’s relaxing functional property.
Promotes ATP Synthesis, Skin Repair and Anti-Aging
HALOGLAS Far-Infrared Energy Beads ATP Synthesis, Skin Repair & Anti-Aging Test
1. Basic Test Information
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Info
Report No.: BJY260127-9180201-02
Issued Date: Mar 31, 2026
Sample: HALOGLAS Far-Infrared Energy Beads
Sample Receipt: Jan 27, 2026
Test Environment: 23 ± 2 ℃, 50 ± 5%RH
Test Cell: Human skin fibroblast HSF7
Test Objective
Evaluate whether HALOGLAS far-infrared material can boost ATP production, repair UV-damaged skin cells and deliver anti-aging effects.
Three Experimental Groups
Normal Control Group: Healthy skin fibroblasts without UV irradiation or far-infrared treatment
UV Aging Model Group: Cells exposed to 10 J/cm² UVA to induce senescence damage (no sample irradiation)
Sample Intervention Group: UVA-senescent cells irradiated by HALOGLAS beads (1–2 cm above plate) for 24h / 48h / 72h
3 Core Detection Indicators
Intracellular ATP content (cellular energy index)
Cell proliferation viability (cell repair capacity via CCK-8)
Type I collagen secretion (key anti-aging skin protein)
2. Detailed Test Data & Analysis
2.1 ATP Synthesis Test (Unit: μmol/L)
Timepoint | Control Avg | UV Model Avg | Sample Avg | ATP Increase vs Model | Significance |
24 h | 18.03 | 10.62 | 10.99 | +3.42% | No significant difference |
48 h | 19.58 | 8.43 | 14.04 | +66.54% | Extremely significant (P<0.01) |
72 h | 20.24 | 5.48 | 12.84 | +134.34% | Extremely significant (P<0.01) |
Analysis: UVA severely depletes cellular ATP. Long-term HALOGLAS far-infrared irradiation drastically restores ATP production, with the strongest energy-boosting effect at 72h. |
2.2 Cell Proliferation Viability (Control = 100%)
Timepoint | Control | UV Model | Sample | Viability Increase vs Model | Significance |
24 h | 100.00% | 76.30% | 86.25% | +13.04% | P<0.01 |
48 h | 100.00% | 72.71% | 79.69% | +9.60% | P<0.01 |
72 h | 100.00% | 61.57% | 79.12% | +28.50% | P<0.01 |
Analysis: UV suppresses cell growth. HALOGLAS effectively repairs damaged fibroblasts and recovers cell proliferation ability, with maximum repair effect after 72h irradiation. |
2.3 Type I Collagen Content (Unit: ng/mL)
Timepoint | Control Avg | UV Model Avg | Sample Avg | Collagen Increase vs Model | Significance |
24 h | 36.78 | 30.11 | 30.77 | +2.17% | No significant difference |
48 h | 38.95 | 29.22 | 32.58 | +11.51% | P<0.01 |
72 h | 40.47 | 24.50 | 31.74 | +29.53% | P<0.01 |
Analysis: UVA breaks down collagen. Continuous far-infrared exposure significantly lifts collagen synthesis in aged skin cells, effectively counteracting UV-induced aging degradation. |
3. Official Report Terms
Valid only with official red test seal, unique anti-counterfeit code and full staff signatures; altered/copied reports are invalid.
Test results only apply to submitted bead samples under this cellular experiment, not clinical medical proof.
Document for internal R&D & scientific research only; cannot be used for legal disputes, medical diagnosis or rights claims.
Report valid for 12 months from issuance date.
4. Comprehensive Conclusion
Cell-level experiments confirm HALOGLAS far-infrared energy beads deliver triple skin-beneficial functions:
Promotes ATP synthesis to replenish cellular energy reserves, especially after long irradiation;
Repairs UVA-damaged skin fibroblasts and recovers cell viability;
Stimulates Type I collagen secretion to mitigate UV-induced skin aging. All three effects strengthen with extended irradiation time, providing laboratory evidence for the material’s energy-replenishing, skin repair and anti-aging properties.
Smoothens Wine Taste
HALOGLAS Energy Glass Vs Ordinary Glass Moutai-Flavored Liquor Comparative Test
1. Basic Test Information
Testing Laboratory
Weipu Technology (Jiangsu) Co., Ltd.
Report No.
SUD55-26010532-JC-01R1
Issued Date
Feb 25, 2026
Client
HEBEI MSD GLASS TECHNOLOGY CO., LTD.
Test Samples
HALOGLAS Far-Infrared Energy Glass Cup
Ordinary Standard Glass Cup (Control Group)
Test Operation Method
Pour identical sauce-flavored Chinese liquor into two cups respectively, stand at room temperature for 20 minutes before full index detection.
Test Standards
GB/T 10345-2022 (Determination of diethyl dibasic acids: pimelic acid, suberic acid, azelaic acid)
GB 12456-21 (Total acid test calculated as acetic acid)
Test Detection Items
Sensory evaluation (color, aroma, taste, style), total acid, ethyl caproate, ethyl lactate, ethyl butyrate, ethyl propionate, ethyl acetate, total acid esters, solids, n-propanol, β-phenylethanol, diethyl dibasic acids.
2. Full Test Data Comparison Table
Test Item | Standard Limit | HALOGLAS Cup Result | Ordinary Glass Cup Result | Change Difference (HALOGLAS vs Ordinary) |
Sensory Appearance | Colorless/pale yellow, clear no sediment | Compliant | Compliant | Consistent |
Aroma | Rich sauce aroma, lasting empty cup fragrance | Compliant | Compliant | Consistent |
Taste | Mellow, balanced long finish | Compliant | Compliant | Consistent |
Typical Style | Distinct sauce liquor character | Compliant | Compliant | Consistent |
Total Acid (g/L, acetic acid) | ≥1.40 | 1.80 | 1.66 | ↑ +0.14 g/L |
Ethyl Caproate (g/L) | ≤0.40 | 0.07 | 0.08 | ↓ -0.01 g/L |
Ethyl Lactate (g/L) | No limit | 0.89 | 0.88 | Slight increase, no obvious change |
Ethyl Butyrate (g/L) | No limit | Not detected | Not detected | No change |
Ethyl Propionate (g/L) | No limit | 0.16 | 0.15 | Slight increase, no obvious change |
Ethyl Acetate (g/L) | No limit | 1.94 | 1.61 | ↑ +20.5% |
Total Acid Esters (mmol/L) | No limit | 77.1 | 77.6 | Minor reduction |
Solids (g/L) | ≤0.70 | 0.27 | 0.23 | Slight increase, still within standard |
N-Propanol (g/L) | No limit | 0.81 | 1.01 | ↓ 19.8% reduction |
β-Phenylethanol (mg/L) | No limit | 72 | 82 | ↓ 12.2% reduction |
Diethyl Dibasic Acids | No limit | Not detected | Not detected | No change |
3. Core Result Analysis
Harsh Fusel Alcohol Reduction (Core Advantage) N-propanol and β-phenylethanol are irritating fusel alcohols that create sharp burning and bitter aftertaste in liquor. After resting in HALOGLAS cup for 20 mins:
N-propanol down 19.8%
β-phenylethanol down 12.2% The material delivers obvious degradation effect on harsh fusel oils, softening liquor’s harsh sensation.
Improved Aroma Ester Retention Ethyl acetate is the key fruit/floral aroma ester of sauce liquor. HALOGLAS raises ethyl acetate content by 20.5%, effectively preventing volatile flavor ester loss and locking in rich liquor fragrance. Ethyl lactate / ethyl butyrate / ethyl propionate remain stable with no negative fluctuation.
Balanced Acid Content Total acid rises moderately from 1.66g/L to 1.80g/L, optimizing the liquor’s mellow, layered taste without over-sourness.
Consistent Sensory Performance Both cups fully meet sauce liquor sensory standards, with identical qualified appearance, aroma, taste and typical style. HALOGLAS only optimizes chemical composition without destroying original liquor flavor characteristics.
4. Official Report Notes
Report is only valid with full official special seal + reviewer & approver signatures; altered or partial copies are invalid.
All test data only applies to this batch of tested liquor and two glass samples, not representative of all liquor batches.
This document is for internal research & quality control only, cannot be used for commercial litigation or official certification evidence.
Any objections to test results must be submitted within 15 working days after receiving the report.
5. Comprehensive Test Conclusion
Compared with ordinary glass cups, HALOGLAS far-infrared energy glass has two core functional advantages for liquor:
Significantly degrades irritating fusel alcohols (n-propanol, β-phenylethanol) to remove harsh burning taste;
Increases key aroma ester ethyl acetate by 20.5%, minimizing flavor substance loss and preserving richer, more balanced wine aroma and taste. The test objectively verifies HALOGLAS’s passive liquor softening function at room temperature with zero electricity or additives required.
Performance on Coffee
HALOGLAS Energy Cup Caffeine Release Test
1. Basic Test Information
Testing Laboratory
WEIPU Technology (Jiangsu) Co., Ltd.
Report Number
SUD55-26010183-JC-01C2En
Issued Date
Jan 27, 2026
Test Period
Jan 12, 2026 – Jan 27, 2026
Client
HEBEI MSD GLASS TECHNOLOGY CO., LTD.
Test Samples
Test Group: HALOGLAS Constellation Far-Infrared Energy Cup
Control Group: Ordinary standard glass cup
Test Standard
GB 5009.139-2014 National Food Safety Standard – Determination of Caffeine in Food
Test Objective
Compare the caffeine release capacity between HALOGLAS energy glass and ordinary glass under identical test conditions.
2. Core Test Data
Sample Group | Caffeine Content Detected | Comparative Performance |
HALOGLAS Constellation Energy Cup | 237 % | 130% higher caffeine release efficiency vs ordinary glass cup |
Ordinary Glass Cup | 183 % | Baseline control value |
Data Analysis
Under unified test conditions, the liquid placed in HALOGLAS energy cup contains significantly higher caffeine concentration. The far-infrared functional material of the glass effectively promotes the dissolution and release of caffeine substances, delivering 130% stronger caffeine release performance than regular glassware.
3. Official Report Terms & Limitations
The report is only valid with the official special test seal plus inspector and approver signatures; modified, tampered or unstamped copies are invalid.
Any objections to test results shall be submitted to WEIPU within 15 working days after report receipt.
This report is only for scientific research, teaching and internal enterprise quality control, and cannot be used as official certification or judicial evidence.
All test results are only valid for the submitted test samples; the client takes full responsibility for the authenticity of sample information.
4. Comprehensive Test Conclusion
Independent third-party detection verifies that HALOGLAS far-infrared energy glass can greatly boost caffeine dissolution. For beverages such as coffee, tea rich in caffeine, the cup helps fully release caffeine ingredients, allowing richer flavor and more sufficient functional substance intake when drinking.
Tea Polyphenol Dissolution
HALOGLAS Constellation Energy Cup Tea Polyphenol Release Test
1. Basic Test Information
Testing Laboratory
WEIPU Technology (Jiangsu) Co., Ltd.
Report Number
SUD55-26010183-JC-01C1En
Issued Date
Jan 27, 2026
Test Cycle
Jan 12, 2026 – Jan 27, 2026
Client
HEBEI MSD GLASS TECHNOLOGY CO., LTD.
Test Samples
Test Group: HALOGLAS Constellation Far-Infrared Energy Cup
Control Group: Ordinary Standard Glass Cup
Test Standard
GB/T 21733-2008 Test Method for Tea Polyphenols
Test Objective
Compare the efficiency of tea polyphenol dissolution & release between HALOGLAS energy glass and ordinary glass under identical experimental conditions.
2. Core Test Data
Sample Group | Detected Tea Polyphenol Content | Comparative Performance |
HALOGLAS Constellation Energy Cup | 0.23 % | 105% higher tea polyphenol release efficiency than ordinary glass cup |
Ordinary Glass Cup | 0.22 % | Baseline control reference value |
Data Analysis
Under consistent testing environments, liquid brewed in the HALOGLAS energy cup contains higher concentrations of tea polyphenols. The proprietary far-infrared material of the glass significantly accelerates the dissolution of tea polyphenols from tea leaves, delivering 105% stronger release capacity compared with regular glass tableware.
3. Official Report Terms & Limitations
This report is only valid when affixed with the official special test seal, plus signatures of inspector and approver; altered, modified or unstamped copies are invalid.
All disputes about test results must be submitted to WEIPU within 15 working days after report issuance.
The document is solely for scientific research, teaching and internal enterprise quality control, and cannot be used as official certification or legal evidence.
Test data only reflects performance of the submitted samples; the client bears full responsibility for the authenticity of sample information provided.
4. Comprehensive Test Conclusion
Third-party independent testing confirms HALOGLAS far-infrared energy glass effectively boosts tea polyphenol extraction during brewing. For tea beverages, this cup maximizes the release of beneficial tea polyphenols, allowing richer tea flavor and better intake of antioxidant active ingredients while drinking.
Dissolution efficiency on Ginseng
HALOGLAS Energy Glass Cup Ginsenoside Dissolution Test
1. Basic Test Information
Testing Institution
WEIPU Technology (Jiangsu) Co., Ltd.
Report Information
Report No.: SUD55-25120559-JC-01R1
Sample Receipt Date: Dec 15, 2025
Test Period: Dec 15, 2025 – Jan 08, 2026
Report Issued Date: Jan 09, 2026
Client
HEBEI MSD GLASS TECHNOLOGY CO., LTD.
Test Samples
Test Group: HALOGLAS Far-Infrared Energy Glass Cup
Control Group: Ordinary Standard Glass Cup
Test Medium & Operation
Changbai Mountain ginseng slices, brewed with hot water at 100°C under unified conditions
Test Standard
NY/T 1043-2016 Green Food – Ginseng and American Ginseng
Test Objective
Compare the dissolution efficiency of total ginsenosides between HALOGLAS functional glass and ordinary glass cups under consistent ginseng brewing conditions.
2. Core Test Data & Analysis
Sample Group | Total Ginsenoside Content (%) | Performance Comparison |
HALOGLAS Energy Glass Cup | 0.48 | Ginsenoside dissolution capacity reaches 252% of ordinary glass cup |
Ordinary Glass Cup | 0.19 | Baseline control value |
Data Interpretation
Under identical high-temperature ginseng brewing conditions, liquid brewed in the HALOGLAS energy glass contains far higher total ginsenoside content. The proprietary far-infrared material of the cup greatly accelerates the release of ginsenosides from ginseng slices, with its active ingredient dissolution effect 2.52 times stronger than conventional glass tableware.
3. Official Report Disclaimer & Validity Rules
The report is invalid without the official dedicated test seal plus signatures of reviewer and approver; any unauthorized modification, addition or deletion voids the whole document.
Copies of this report are only valid if re-stamped with the special report seal.
Any objections to test results shall be submitted to WEIPU within 15 working days after receiving the report.
This report is only for scientific research, teaching and internal enterprise quality control; it has no official certification effect and cannot be used for legal disputes or commercial proof.
Test data only represent the submitted test samples, and the client takes full responsibility for the authenticity of sample information.
This revised report replaces the original document SUD55-25120559-JC-01, which becomes invalid upon issuance of this report.
4. Comprehensive Test Conclusion
Third-party independent lab detection proves that HALOGLAS far-infrared energy glass delivers outstanding performance in promoting ginsenoside dissolution during ginseng brewing. Using this functional cup maximizes the precipitation of ginseng’s core beneficial ginsenosides, allowing higher intake of nutritional active ingredients and richer ginseng flavor when drinking ginseng infusion.
Liquid Water Isotope Test
HALOGLAS effect on Liquid Water Isotope Test
1. Basic Test Information
Testing Institution
Beijing Qingxi Technology Research Institute
Report Details
- Report No.: BT2601300019
- Test Period: Feb 04, 2026 – Mar 24, 2026
- Issued Date: Mar 24, 2026
Client
HEBEI MSD GLASS TECHNOLOGY CO., LTD.
Test Sample
- Raw water: Water before immersion with HALOGLAS far‑infrared energy stones
- Treated water: Water after immersion with HALOGLAS far‑infrared energy stones
Test Instrument
GSPC‑I26 Liquid Water Isotope Analyzer
Test Item
Measure hydrogen‑isotope parameters (δ²H and D/H ratio) of water before and after contact with HALOGLAS energy stones, to observe isotope‑related variation characteristics of liquid water.
2. Core Test Result
| Sample | δ²H (‰) | D/H (×10⁻⁶) |
|---|---|---|
| Water before HALOGLAS stone immersion | -58.25 | 146.93 |
| Water after HALOGLAS stone immersion | -39.73 | 149.82 |
Data Analysis
- After immersion with HALOGLAS far‑infrared energy stones, the δ²H value of water increased from ‑58.25 ‰ to ‑39.73 ‰.
- The D/H isotopic ratio rose from 146.93 ×10⁻⁶ to 149.82 ×10⁻⁶.
- The test captures measurable change in hydrogen‑isotope index of liquid water after interaction with HALOGLAS functional material under laboratory conditions.
Promotes Wheat Seed Germination
HALOGLAS Bowl Wheat Seed Germination Test
1. Basic Test Information
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Information
Report ID: BJY260130-9180201~02
Issued Date: Mar 23, 2026
Sample Submission Date: Jan 30, 2026
Test Environment: 22 ± 3℃, relative humidity 30 ± 10%RH
Test Samples
Test Group: HALOGLAS Far-Infrared Glass Bowl
Control Group: Ordinary Standard Glass Bowl
Test Objective
Compare the influence of HALOGLAS functional glass and ordinary glass on wheat seed germination time and germination rate under identical cultivation conditions.
Test Material
Uniform, intact, mildew-free wheat seeds; 30 seeds for each group (60 seeds total).
Cultivation & Testing Equipment
Electronic analytical balance, vernier caliper, digital camera, temperature & humidity meter.
2. Experimental Method
Seed Pre-treatment: Disinfect wheat seeds with 75% alcohol for 30s, rinse 3–4 times with distilled water to eliminate microbial interference.
Group Setting: Randomly divide seeds into two groups, 30 seeds per bowl with consistent soil moisture and seed spacing.
Unified Cultivation: Both groups placed under natural sunlight with consistent temperature, humidity and ventilation; regular watering and synchronous observation.
Judgment Standard for Germination: Radicle breaks through seed coat (white tip visible); record the exact germination time of each seed separately.
3. Core Test Data & Analysis
Group | Average Germination Time | Germination Rate | Key Comparison |
Ordinary Glass Bowl | 34 h | 87% | Control benchmark |
HALOGLAS Bowl | 30 h | 87% | Germination time shortened by 11.8% |
Data Interpretation
The two groups show identical final germination rate (87%), which proves HALOGLAS material does not change the overall germination success rate of wheat seeds.
The average germination cycle of seeds cultured in HALOGLAS bowl is 11.8% shorter than the ordinary bowl group, which means the far-infrared energy of HALOGLAS effectively accelerates seed germination and speeds up the early growth process of wheat seeds.
Visual growth photos also reflect that wheat seedlings in the HALOGLAS group enter the budding stage faster than the control group.
4. Official Report General Provisions
The report is only valid with official red special seal, unique anti-counterfeit code, plus signatures of preparer, reviewer and approver; altered, copied or tampered versions are invalid.
All test results are only for the submitted samples under this specific experimental condition, cannot be used as legal evidence, litigation basis or medical certification.
This document is limited to scientific research, teaching and enterprise internal product development; the report is valid for 12 months from issuance date.
The laboratory strictly keeps all test data confidential without client’s authorization.
5. Comprehensive Test Conclusion
Biological cultivation experiments verify that HALOGLAS far-infrared glass bowl can significantly accelerate wheat seed germination speed without affecting the final germination rate. It shortens the average germination time by 11.8%, demonstrating that the far-infrared functional material can activate seed vitality and promote early budding growth of plant seeds. This provides biological experimental evidence for the material’s ability to boost substance activity and cell vitality.
Piezoelectric Constant and Seebeck Coefficient
HALOGLAS Bracelet Piezoelectric Constant & Seebeck Coefficient Test
1. Basic Test Information
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Details
Report No.: BJY260123-9180101
Issued Date: Feb 09, 2026
Sample Submission Date: Jan 28, 2026
Test Environment: 23 ± 2℃, 50 ± 5%RH
Test Sample
HALOGLAS Healthy Bracelet (Glass Energy Beads)
Test Equipment
ZJ-3 Piezoelectric Tester (for piezoelectric constant test)
Portable PTM-3 Seebeck Coefficient Tester (for thermoelectric performance test)
Test Objectives
Quantitatively test two core physical parameters of the functional glass beads: piezoelectric constant and Seebeck coefficient, to verify the material’s weak piezoelectric and thermoelectric properties.
2. Core Test Data
Test Item | Test Result | Unit | Parameter Explanation |
Piezoelectric Constant | 1 | pC/N | Represents the ability of the material to generate weak electric charge under mechanical pressure/vibration |
Seebeck Coefficient | < 0.1 | μV/K | Represents the thermoelectric voltage generated by the material under temperature difference; the value reflects weak thermoelectric response |
Data Analysis
Piezoelectric constant reaches 1 pC/N, which proves the glass material possesses mild piezoelectric effect: slight mechanical friction, vibration or squeezing can induce tiny electric charges inside the beads.
The Seebeck coefficient is lower than 0.1 μV/K, indicating the material generates weak thermoelectric micro-current when exposed to temperature changes (body temperature difference, ambient temperature fluctuation).
Combined piezoelectric and thermoelectric properties are the fundamental physical sources of the material’s far-infrared energy activity, explaining its ability to alter water molecular clusters and activate biological substance dissolution observed in previous tests.
3. Official Report Terms & Limitations
The report is only valid with official red special research test seal plus signatures of compiler, reviewer and approver; copied, altered or tampered reports are invalid.
All test data only apply to the submitted glass bead sample under fixed test conditions; different test environments may produce different results.
This research report is for enterprise internal R&D, scientific research and quality control only, and cannot be used as judicial evidence, commercial certification or legal basis for disputes.
The report is valid for 12 months from the issuance date; the laboratory keeps all test data strictly confidential without client consent.
The testing institution is only responsible for the physical performance of the submitted sample, and shall not be liable for the batch products of the client.
4. Comprehensive Test Conclusion
Third-party physical performance testing confirms that HALOGLAS functional glass beads have measurable piezoelectric constant and weak thermoelectric (Seebeck) coefficient. The material can produce micro-electric effects under mechanical force and temperature variation. These inherent weak physical energy characteristics form the physical foundation of the material’s far-infrared radiation capacity, supporting the series of functional effects including optimizing water molecular structure, boosting dissolution of nutritional ingredients and activating biological cell vitality validated in prior cell, brewing and seed germination experiments.
Dissolution & Retention of Active Substances in Guizhi Decoction
HALOGLAS Bowl Health Pot – Dissolution & Retention of Active Substances in Guizhi Decoction Test
1. Basic Test Information
Testing Institution
Beijian (Beijing) Research Institute of Testing Technology (BJTC)
Report Details
Report ID: BJY261013-9180401~02
Issued Date: Nov 03, 2026
Sample Submission Date: Oct 13, 2026
Test Environment: 23 ± 2℃, 50 ± 5%RH
Test Samples
Test Group A: HALOGLAS Bowl Health Pot (HALOGLAS bowl + health pot + HALOGLAS strainer)
Control Group B: Ordinary Health Pot (ordinary glass bowl + ordinary health pot, direct decant without special strainer)
Test Objective
Evaluate whether HALOGLAS Bowl Health Pot system improves dissolution and retention of core bioactive ingredients in traditional Chinese herbal formula Guizhi Decoction (Cinnamon Twig Decoction) under identical herbal decocting workflow.
Tested Active Ingredients
| Raw Herbal Material | Target Analyte | Functional Role |
|---|---|---|
| Cinnamomi Ramulus (Cassia Twig) | Cinnamaldehyde | Core volatile active component |
| Paeoniae Radix Alba (White Peony Root) | Paeoniflorin | Key ingredient for harmonizing nutrient-defensive qi |
| Honey-fried Licorice | Liquiritin, Glycyrrhizic Acid | Herb-harmonizing therapeutic constituents |
| Fresh Ginger | 6-Gingerol | Warming and diaphoretic biosubstance |
| Chinese Date | Total Polysaccharides | Qi-tonifying nutrient component |
2. Experimental Procedure
Both groups followed identical decoction workflow:
Soaking: Guizhi Decoction herbs soaked in room-temperature water for 1 hour (water level 2–3 cm above herbs).
Heating: Transfer herbs + soaking water into health pot; top up water to 1.1 L; bring to rolling boil then simmer gently for 30 min.
Separation & cooling:
Group A: Decoctant filtered via HALOGLAS bowl strainer, cooled to 40 °C for testing.
Group B: Directly pour out supernatant, discard residue, cool to 40 °C for testing.
3. Core Quantitative Test Results
| Test Component | HALOGLAS Bowl Health Pot (Group A) | Ordinary Health Pot (Group B) | Percentage Increase |
|---|---|---|---|
| Total Polysaccharides (mg/L) | 997.86 | 915.71 | +8.97% |
| 6-Gingerol (mg/L) | 0.985 | 0.383 | +157.2% |
| Cinnamaldehyde (mg/L) | 31.38 | 12.81 | +145.0% |
| Liquiritin (mg/L) | 6.12 | 5.10 | +20.0% |
| Glycyrrhizic Acid (mg/L) | 39.62 | 35.63 | +11.2% |
| Paeoniflorin (mg/L) | 311.85 | 286.17 | +8.97% |
Ranking by magnitude of increase
6-Gingerol (+157.2 %) — Fresh Ginger
Cinnamaldehyde (+145.0 %) — Cassia Twig
Liquiritin (+20.0 %) — Honey-fried Licorice
Glycyrrhizic Acid (+11.2 %) — Honey-fried Licorice
Total Polysaccharides (+8.97 %) — Chinese Date
Paeoniflorin (+8.97 %) — White Peony Root
4. Result Analysis
Volatile / heat-sensitive components show dramatic improvement: 6-Gingerol and cinnamaldehyde are volatile, heat-labile substances. The HALOGLAS system greatly preserves these two ingredients (+157.2 % and +145.0 %). The report suggests that the strainer may have reduced vapor escape during pouring or retained more volatile components adhering to herbal residues during filtration.
Water-soluble ingredients have moderate gains: Total polysaccharides, paeoniflorin, glycyrrhizic acid increase moderately (+8.97 % ~ +11.2 %). The report suggests this may be attributed to more thorough filtration, reducing liquid retention loss in the herbal residue.
Difference within licorice-derived markers: Liquiritin (+20.0 %) outperforms glycyrrhizic acid (+11.2 %). The report suggests this difference may be related to molecular polarity and adsorption behaviour on herb residues.
Overall performance: All six measured active-substance markers are higher in Group A. The promotion range spans from +8.97 % up to +157.2 %. The protective effect is most prominent for volatile herbal constituents.
5. Comprehensive Test Conclusion
Under standardized Guizhi Decoction boiling-decoction conditions, the HALOGLAS Bowl Health Pot system raises measurable concentrations of all six core active substances compared with ordinary healthpot equipment.
Outstanding protective effect for volatile heat-sensitive herbal ingredients (6-gingerol, cinnamaldehyde).
Steady improvement of water-soluble therapeutic components. This lab result demonstrates that HALOGLAS functional glass hardware can enhance dissolution and retention of multiple active ingredients in traditional Chinese herbal decoctions.
Note: This is laboratory research-test data, not clinical medical evidence.